Show simple item record

dc.contributor.authorAbuga, Kennedy O.
dc.contributor.authorChepkwony, Hezekiah K.
dc.contributor.authorRoets, Eugene
dc.contributor.authorHoogmartens, Jos
dc.date.accessioned2013-02-18T13:33:13Z
dc.date.issued2001-11
dc.identifier.citationJ. Sep. Science, 24: 849–855.en
dc.identifier.urihttp://erepository.uonbi.ac.ke:8080/xmlui/handle/123456789/10125
dc.description.abstractClarithromycin is a 6-O-methylated semi-synthetic derivative of erythromycin A, which is more resistant towards acid decomposition. Commercial clarithromycin samples contain several potential impurities arising from the manufacturing process and degradation. A simple, selective, and sensitive isocratic liquid chromatographic method has been developed for the impurity profiling of clarithromycin bulk samples. The method employs a XTerra RP18, 5 μm, 250×4.6 mm column thermostated at 56°C. The mobile phase consists of acetonitrile – 0.2 M potassium phosphate buffer pH 6.80 – water (40 : 3.5 : 56.5). Several peaks are of unknown identity. The method is stability indicating.en
dc.language.isoenen
dc.subjectLiquid chromatographyen
dc.subjectClarithromycinen
dc.subjectXTerra RP18en
dc.titleA stability-indicating HPLC method for the separation of clarithromycin and related substances in bulk samplesen
dc.typeArticleen
local.embargo.terms6 monthsen
local.embargo.lift2013-08-17T13:33:13Z


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record