Protamine--the need to determine the dose. Comparison of a simple protamine titration method with an empirical dose regimen for reversal of heparinisation following cardiopulmonary bypass.
View/ Open
Date
1991Author
Keeler, JF
Shah, MV
Hansbro, SD
Type
ArticleLanguage
enMetadata
Show full item recordAbstract
A simple method of protamine titration using the Hemochron system was compared with an empirical dose protocol for reversal of heparinisation following cardiopulmonary bypass in 40 patients undergoing elective myocardial revascularisation. Protamine titration revealed a wide range for protamine requirement and resulted in a significant reduction in protamine dose compared with the empirical dose protocol (p less than 0.01). Heparin reversal was assessed as adequate in all patients. The titration technique was easy and straightforward to use in the operating theatre.
URI
www.ncbi.nlm.nih.gov/whalecom0/pubmed/1750591http://erepository.uonbi.ac.ke:8080/xmlui/handle/123456789/30906
Citation
Anaesthesia. 1991 Nov;46(11):925-8.Publisher
Department of Anaesthesia, General Infirmary, Leeds.
Collections