Show simple item record

dc.contributor.authorRouet, F
dc.contributor.authorFoulongne, V
dc.contributor.authorViljoen, J
dc.contributor.authorSteegen, K
dc.contributor.authorBecquart, P
dc.contributor.authorValéa, D
dc.contributor.authorDanaviah, S
dc.contributor.authorSegondy, M
dc.contributor.authorVerhofstede, C
dc.contributor.authorVan de Perre, P
dc.contributor.authorWHO/ANRS 1289 Kesho Bora Study Group.
dc.contributor.authorTemmerman, M
dc.date.accessioned2013-06-12T09:53:31Z
dc.date.available2013-06-12T09:53:31Z
dc.date.issued2010-02
dc.identifier.citationJ Virol Methods. 2010 Feb;163(2):253-7. doi: 10.1016/j.jviromet.2009.10.005. Epub 2009 Oct 27en
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/pubmed/19837114
dc.identifier.urihttp://erepository.uonbi.ac.ke:8080/xmlui/handle/123456789/32162
dc.description.abstractThe implementation of cost effective HIV-1 RNA quantitation assays in resource-poor settings is of paramount importance for monitoring HV-1 infection. A study comparing the analytical performance of three HIV-1 RNA assays (Generic HIV Viral Load, Amplicor v1.5 and Nuclisens EasyQ v1.2) was performed on 160 plasma samples from 160 consecutive antiretroviral treatment naive HIV-1-infected pregnant women assessed for eligibility in the Kesho Bora trial aimed at prevention of mother-to-child transmission of HIV-1 in three African countries (Burkina Faso, Kenya and South Africa). Correlation and agreement of results of the three assays were assessed for plasma HIV-1 RNA quantitation in specimens harbouring mainly sub-subtype A1, subtype C, and circulating recombinant form (CRF) 02_AG and CRF06_cpx. Good degrees of correlation and agreement were observed between these HIV-1 RNA assays. However, nine (9/160, 5.6%) strains detectable with the Generic HIV Viral Load assay were not detected by either the Amplicor (n=7) or EasyQ (n=2) test. One strain (0.6%) was missed with the Generic HIV Viral Load assay. Further, concordantly positive plasma samples harbouring CRF02_AG and CRF06_cpx yielded significantly higher HIV-1 RNA concentrations when tested by Generic HIV Viral Load, as compared to Amplicor v1.5 (mean differences, +0.33 and +0.67 log(10) copies/ml; P=0.0004 and P=0.002, respectively). The Generic HIV Viral Load assay accurately quantified the majority of the non-B HIV-1 subtypes assessed in this study. Due to its low cost (approximately 10 US $/test), this assay performed with open real-time PCR instruments is now used routinely in the Kesho Bora trial and may be recommended in other African settingsen
dc.language.isoenen
dc.publisherUniversity of Nairobi.en
dc.titleComparison of the Generic HIV Viral Load assay with the Amplicor HIV-1 monitor v1.5 and Nuclisens HIV-1 EasyQ v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: the Kesho Bora preparatory studyen
dc.typeArticleen
local.publisherDepartment of Medicineen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record