Morphometry of the Myopectineal Orifice: Relevance in Prosthesis Hernia Repair.
View/ Open
Date
2014Author
Ndung’u, BM
Koech, A.C
Tharao, M.K
Language
enMetadata
Show full item recordAbstract
Background: All groin hernias occur through a weakness at the lower extremity of the
abdomen: the myopectineal orifice (MPO). Open preperitoneal and laparoscopic techniques
involve dissection and placement of the prosthetic mesh to cover all potential hernia sites of
the MPO. We re-examined the preperitoneal anatomy with the aim of determining the
minimum ideal shape and size of prosthetic mesh for the repair of inguino-femoral hernias.
Methods: Dissection was performed on 15 preserved human adult cadavers of both sexes.
The preperitoneal approach was used to access the myopectineal orifice and its shape and
dimensions obtained from tracings. The surface area was obtained by point counting.
Results: The shape of the MPO was trapezoid and its area 7.0 ± 1.29cm2. The maximum
length was 5.7cm and the maximum width 2.9cm. The point of maximum width varied
along the length and the area of the MPO was significantly larger in male.
Conclusion: For preperitoneal placement of prosthesis, a rectangular mesh measuring
15cm by 12cm is appropriate. These dimensions ensure adequate coverage and overlap of
all the potential hernia sites in the groin, as well as allowing for mesh shrinkage.